Language

+86-513 8659 8187

Domestic RO Membrane 1812

Home / Products / Domestic RO Membrane / Domestic RO Membrane 1812 / Reverse Osmosis Membrane Elements RO-1812-100

Reverse Osmosis Membrane Elements RO-1812-100

Reverse Osmosis Membrane Elements RO-1812-100 is an upgraded option for standard small RO systems and household water purifiers, built on the practicality of the 1812-75 model while delivering enhanced performance. Its key improvement lies in the adoption of a higher flux membrane sheet: under the same membrane area and testing conditions, this upgrade enables significantly greater water production compared to the 1812-75—perfect for families with higher daily water demand, ensuring ample clean water supply for drinking, cooking, and daily use. Beyond increased output, the higher flux design also helps save energy consumption during operation, further reducing long-term operating costs for households. Like its counterpart, it maintains reliable purification capabilities to lower water TDS levels and improve taste, making it an ideal fit for households that want to meet their daily high water needs without compromising on energy efficiency or long-term cost savings.

+86-513 8659 8187

[email protected]

Category Introduction

The Domestic Ro Membrane 1812 is the core filter element for home reverse osmosis water purification systems, ensuring compatibility with most household water purification equipment. Its core function is to utilize its precision semi-permeable membrane to effectively remove dissolved salts, heavy metals, bacteria, viruses, and organic contaminants from tap water, thereby producing pure, reliable drinking water.

The core performance of products in the Domestic Ro Membrane 1812 category is reflected in high salt rejection rates and stable water output, ensuring pure water quality while meeting daily household drinking water needs. These products typically utilize a multi-layer composite membrane for enhanced filtration accuracy, feature an automatic flushing function for extended service life, and feature a rugged housing design for leak-free operation. Choosing the reliable Domestic Ro Membrane 1812 is crucial to ensuring the health and purity of your family's drinking water.

Product Information

Model Stable Rejection  Min Rejection GPD(L/min)
RO-1812 1812-100 96 95 100(0.26)
Testing Conditions Operating pressure 60psi (0.41MPa)
Test solution temperature 25 ℃
Test solution concentration (NaCl) 500 ppm
PH value  7-8
Recovery rate of a single membrane element 40%
Flow range of a single membrane element ±15%
Operating Conditions & Limits Maximum operating pressure 300 psi(2.07MPa)
Maximum temperature 45 ℃
Maximum feedwater flow SDI15 5
Maximum concentration of free chlorine: <0.1ppm
Allowed pH range for chemical cleaning 3-10
Allowed pH range for feedwater in operation 2-11
Maximum pressure drop per element 10psi(0.07MPa)
Message Feedback